Re: new turbine
by Ted Marynicz
at 2008-08-11 14:46:29
(Forum::Public::Wind)
Be careful with the combination of grid-tied wind turbine and ground source heat pump.
The initial load taken by the compressor of a GSHP can cause sufficient fluctuation in the grid voltage for the inverter to see it as a disconnection, which can cause the inverter to reset itself. If this happens when the turbine is generating then you will loose the output. Be sure you have over-voltage protection on the DC input to the inverter to allow for this.
You can get soft-start devices for the GSHP that will help with the problem too.
ted
new turbine
|
noel maguire - 29/06 |
Re: new turbine
|
CL - 30/06 |
Re: new turbine
|
noel maguire - 30/06 |
Re: new turbine
|
CL - 1/07 |
Re: new turbine
|
noel maguire - 2/07 |
Re: new turbine
|
CL - 11/08 |
Re: new turbine
|
Ted Marynicz - 11/08 |
Re: new turbine
|
noel maguire - 11/08 |
Re: new turbine
|
noel maguire - 11/08 |